Fujiro FJ10001st Gen
Recovers gold and silver from plating and stripping solutions.

Recovers gold and silver from plating and stripping solutions.

Recovers gold and silver from plating and stripping solutions. Same capacity as the FJ1000.
Same recovery capacity as Fujiro FJ1000.
| Property | Value |
|---|---|
| Recovery method | Electrolysis on a rotating titanium cathode |
| Size | FJ1000: 300 × 450 × 600 mm. FJ1500: to be confirmed. |
| Solution treated per day, silver | 150 to 200 L/day |
| Solution treated per day, gold | 100 to 150 L/day |
| Working voltage, gold | 1.6 to 2.6 V |
| Working voltage, silver | 1.5 to 1.8 V |
| Voltage | 220 V |
| Power | 300 W |